Shenzhen ZYH Hardware and Plastic Products Co., Ltd. +86 189 2939 4378 nickcopy698@gmail.com

Sep 18, 2026 · BLOG

The symptom

Parts from different cavities vary in weight by more than one percent, some flash while others short-shot, and the operator keeps adjusting pressure to chase the problem.

The cause

An unbalanced runner delivers melt to cavities at different pressures and temperatures. With large parts such as crates, the flow length difference is enough to change the filling pattern completely.

The fix

Geometrically balanced runners for symmetric parts, or flow simulation plus valve-gate sequencing for family moulds. We verify balance on T1 by weighing parts from every cavity.